Pressure Pump Controllers

The DCC Pressure Pump Controllers are designed to work with pressure sensors to automatically control either single or variable speed pumps for pressure booster stations, filling tanks, and other fluid pumping applications.

Controllers include:


Pressure Controller Series II and Pressure Booster Pump Controllers

The Pressure Controller Series II (PC2) and Pressure Booster Pump Controllers (PBC) automatically control single speed pumps to maintain a specific pressure level between setpoints. They are designed to be the heart of pump control systems for pressure booster stations, tanks, buildings, and other fluid pump-up applications.

Features include:

  • Two models available to control up to 4 pumps with built-in alternation and time delay between pump starts.
  • Accepts 2 types of sensors including any 4-20 mA pressure transmitters and floats switches.
  • Automatically selects a backup sensor in the event the primary sensor fails. If the primary sensor fails then the system will operate on backup floats or a backup 4-20 mA signal sensor (optional).
  • Setpoints adjustable from front panel or remotely via serial port.
  • Low supply pumps shutdown input.
  • Bargraph displays pressure and setpoints.
  • Pumps, sensors, and alarms status indicators on front panel.
  • Front panel test knob for simulated pressure input testing.
  • 4-20 mA signal output proportional to pressure.
  • RS-232 serial port for SCADA communications support and PC interfacing.
  • Uses non-volatile memory allowing system to retain program software and setpoints during power loss.

Model Name

Model No.

Description

Datasheet (PDF)

Pressure Controller Series II (PC2)

11928-8

Controls up to 2 constant speed pumps. Supply voltage: 12 VAC. 4-20 mA sensor input. Inputs for float switches and pump disables. Pumps and alarms output relays: 15A at 125 VAC. RS-232 serial port.

11928-8 DS

Pressure Booster Pump Controller (PBC)

11436-8

Controls up to 4 constant speed pumps. Supply voltage: 12 VAC or 15-40 VDC. 4-20 mA or 0-5 VDC isolated analog inputs (optional). 4-20 mA isolated analog outputs (optional). Isolated digital inputs. Expanded I/O capability. Numerical display. Pumps and alarms output relays: 20A at 250 VAC. RS-232 serial ports.

11436-8 DS

Options
AS11470 Analog I/O Module
IC3 Isolated Analog Output (1 ea.)
IC4 Isolated Analog Input (1 ea.)
SW9 On-board pressure transducer 5 psig
SW10 On-board pressure transducer 15 psig

Universal Pressure Booster Pump Controller

The Universal Pressure Booster Pump Controller (UPBC) is designed to work with pressure sensors to control constant speed pumps or variable speed pumps for booster stations, tanks, buildings, and other fluid pump-up applications where proportional flow or pressure is required.

Features include:

  • Controls up to 4 pumps with built-in alternation and time delay between pump starts.
  • Controls variable and single speed pumps.
  • Minimum speed adjustment.
  • Field adjustable PID control loop from front panel.
  • Maintains preset system pressure.
  • Isolated inputs and outputs (optional).
  • Accepts 2 types of sensors including most pressure sensors and floats switches.
  • Automatically selects a backup sensor in the event the primary sensor fails.
  • Low supply pumps shutdown input.
  • Connection for battery backup with built-in charger.
  • Setpoints adjustable from front panel or remotely via serial port.
  • LED numeric and dual bargraph readout.
  • Pumps, sensors, and alarms status indicators on front panel.
  • Front panel test knob for simulated pressure input testing.
  • RS-232 serial port for SCADA communications support and PC interfacing.
  • Uses non-volatile memory allowing system to retain program software and setpoints during power loss.

Model Name

Model No.

Description

Datasheet (PDF)

Universal Pressure Booster Pump Controller
(UPBC)

12126

Controls up to 4 constant or variable speed pumps. Supply voltage: 12 VAC or 15-40 VDC. 4-20 mA or 0-5 VDC isolated analog inputs (optional). 4-20 mA isolated analog outputs (optional). Isolated digital inputs. Expanded I/O capability. Numerical display. Pumps and alarms output relays: 20A at 250 VAC RS-232 serial ports.

12126 DS

Options
AS11470 Analog I/O Module
IC3 Isolated Analog Output (1 ea.)
IC4 Isolated Analog Input (1 ea.)
SW9 On-board pressure transducer 5 psig
SW10 On-board pressure transducer 15 psig